AD4115BCPZ-RL7
Analog Devices Inc.
- Lifecycle
- Active
- Stock
- 4071 Stückzahl
- Package
- VFQFN-40
- Series
- Datenerfassung mit Analog to Digital Converters (ADC)
Dieser detaillierte Vergleich von AD4115BCPZ-RL7 und AD4111BCPZ-RL7 bietet wertvolle Einblicke in deren Spezifikationen und Hauptmerkmale. Wir gehen ausführlich auf wichtige Faktoren ein, darunter RoHS-Konformität, REACH-Status, Serie, Montageart, Gehäusetyp und weitere relevante Eigenschaften. Die übersichtliche Darstellung der Unterschiede vereinfacht die Komponentenauswahl und erleichtert Ihnen die Wahl der optimalen Lösung für Ihre Anwendung.
Replacement verdict
The AD4111BCPZ-RL7 and AD4115BCPZ-RL7 share the same LFCSP-40 package, 24-bit sigma-delta architecture, and SPI interface, making them pin-compatible and functionally interchangeable in many precision measurement designs. However, the AD4111 integrates dedicated current-channel inputs with open-wire detection, while the AD4115 provides a higher channel count and faster output data rate. Engineers must validate channel configuration, input range, and system calibration against the target application before substituting one for the other.
Analog Devices Inc.
Analog Devices Inc.
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | AD4111BCPZ-RL7 | AD4115BCPZ-RL7 | Why it matters |
|---|---|---|---|
| Number of Input Channels | 8 single-ended / 4 differential | 16 single-ended / 8 differential | Determines how many sensor signals can be digitized simultaneously, directly affecting system channel density and board layout. |
| ADC Architecture | Sigma-Delta (24-bit) | Sigma-Delta (24-bit) | Both use sigma-delta conversion, providing high resolution and noise rejection suitable for precision industrial measurement. |
| Input Types Supported | Voltage and current inputs | Voltage inputs only | Current-input capability allows direct interfacing with 4-20 mA industrial sensors without external burden resistors. |
| Maximum Input Voltage Range | ±10 V | ±10 V | Defines the maximum signal amplitude the ADC can directly accept, impacting compatibility with industrial voltage transmitters. |
| Current Input Range | ±20 mA | Not supported | The AD4111 can directly measure current-loop sensors, while the AD4115 requires external signal conditioning for current inputs. |
| Interface | SPI | SPI | SPI is a standard serial interface for connecting ADCs to microcontrollers, ensuring straightforward digital integration. |
| Package | 40-lead LFCSP (6 mm × 6 mm) | 40-lead LFCSP (6 mm × 6 mm) | Identical package footprint enables drop-in PCB compatibility between the two devices. |
| Supply Voltage (AVDD) | 4.5 V to 5.5 V | 4.5 V to 5.5 V | Matching analog supply requirements simplifies power supply design and allows shared rails. |
| Operating Temperature Range | −40 °C to +105 °C | −40 °C to +105 °C | Industrial temperature range ensures reliable operation in harsh environments. |
| Internal Reference | 2.5 V | 2.5 V | An integrated precision reference reduces external component count and improves measurement accuracy. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | AD4115BCPZ-RL7 | AD4111BCPZ-RL7 |
|---|---|---|
| Part Status | Active | Active |
| Number of Bits | 24 | 24 |
| Sampling Rate(Per Second) | 125k | 6.2k |
| Number of Inputs | 8, 16 | 4, 8 |
| Input Type | Differential, Single Ended | Differential, Single Ended |
| Data Interface | DSP, MICROWIRE™, QSPI™, and SPI™ | Serial, SPI |
| Configuration | MUX-ADC | MUX-S/H-ADC |
| Ratio - S / H: ADC | 0:1 | 0:1 |
| Number of A/D Converters | 1 | 1 |
| Architecture | Sigma-Delta | Sigma-Delta |
| Reference Type | External, Internal | External, Internal |
| Voltage - Supply, Analog | 4.5V ~ 5.5V | 2V ~ 5.5V |
| Voltage - Supply, Digital | 2V ~ 5.5V | 2V ~ 5.5V |
| Features | Temperature Sensor | Internal Oscillator, Temperature Sensor |
| Operating Temperature | -40°C ~ 105°C | -40°C ~ 105°C |
The AD4111BCPZ-RL7 is a 24-bit sigma-delta ADC with ±10 V and 0-10 V inputs, supporting up to 8 single-ended or 4 differential channels, and includes open-wire detection and overvoltage protection. The AD4115BCPZ-RL7 is a 24-bit sigma-delta ADC with ±10 V inputs, supporting up to 16 single-ended or 8 differential channels, but does not include the open-wire detection or overvoltage protection features of the AD4111. Both are in a 40-lead LFCSP package.
No. Although both devices are offered in a 40-lead LFCSP package, they are not pin-compatible. The AD4111 includes additional pins for open-wire detection and overvoltage protection, and the pin functions differ. Designers must consult the respective datasheets for pin configurations.
No. The two devices have different channel counts, input voltage ranges, and feature sets. The AD4111 supports 8 single-ended/4 differential channels with ±10 V and 0-10 V ranges, while the AD4115 supports 16 single-ended/8 differential channels with ±10 V range only. A direct substitution would require hardware and software modifications.
The AD4111BCPZ-RL7 supports up to 8 single-ended or 4 differential input channels. The AD4115BCPZ-RL7 supports up to 16 single-ended or 8 differential input channels.
No. Only the AD4111BCPZ-RL7 includes open-wire detection capability. The AD4115BCPZ-RL7 does not provide this feature.
The AD4111BCPZ-RL7 supports ±10 V and 0-10 V input ranges. The AD4115BCPZ-RL7 supports only ±10 V input range.
Both the AD4111BCPZ-RL7 and AD4115BCPZ-RL7 are available in a 40-lead LFCSP (lead frame chip scale package). The suffix "RL7" indicates tape and reel packaging with 7-inch reel diameter.
The AD4115BCPZ-RL7 is better suited for high-channel-count applications because it supports up to 16 single-ended or 8 differential channels, whereas the AD4111BCPZ-RL7 supports up to 8 single-ended or 4 differential channels.
Both the AD4111BCPZ-RL7 and AD4115BCPZ-RL7 require an external reference voltage for operation. Neither device includes an internal reference. Designers must provide a suitable external reference according to the datasheet specifications.