ADS114S08IPBS vs ADS1198CPAG

Dieser detaillierte Vergleich von ADS114S08IPBS und ADS1198CPAG bietet wertvolle Einblicke in deren Spezifikationen und Hauptmerkmale. Wir gehen ausführlich auf wichtige Faktoren ein, darunter RoHS-Konformität, REACH-Status, Serie, Montageart, Gehäusetyp und weitere relevante Eigenschaften. Die übersichtliche Darstellung der Unterschiede vereinfacht die Komponentenauswahl und erleichtert Ihnen die Wahl der optimalen Lösung für Ihre Anwendung.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1198CPAG and ADS114S08IPBS are not drop-in replacements for one another. The ADS1198CPAG is an eight-channel, 16-bit biopotential measurement front end with an integrated programmable gain amplifier and a maximum data rate of 8 kSPS, while the ADS114S08IPBS is a sixteen-channel, 16-bit delta-sigma ADC supporting data rates up to 2 kSPS. Their channel counts, package footprints, and target signal chains differ substantially, so substituting one for the other requires a full schematic and layout redesign rather than a direct swap.

Different channel count Different package footprint Different maximum data rate Different input architecture

Parts at a glance

Part A

ADS114S08IPBS

Texas Instruments

Lifecycle
Active
Stock
4543 Stückzahl
Package
TQFP-32
Series
Datenerfassung mit Analog to Digital Converters (ADC)
Part B

ADS1198CPAG

Texas Instruments

Lifecycle
Active
Stock
3254 Stückzahl
Package
TQFP-64
Series
Datenerfassung mit dem Analog Front End (AFE)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1198CPAG ADS114S08IPBS Why it matters
Resolution (bits) 16 16 Both are 16-bit delta-sigma ADCs, so nominal resolution is equivalent for signal acquisition.
Number of input channels 8 12 Channel count determines how many sensors or electrodes can be connected without external multiplexing.
Maximum sample rate (SPS) 8000 2000 Higher sample rate supports faster signal bandwidth and better capture of dynamic waveforms.
Programmable gain amplifier (PGA) Yes (1 to 12) Yes (1 to 128) PGA gain range affects the ability to resolve small signals from low-amplitude sensors.
Supply voltage (analog) 2.7 V to 5.25 V (unipolar); ±2.5 V (bipolar) 2.7 V to 5.25 V (analog); 1.7 V to 3.6 V (digital) Supply requirements determine compatibility with the host system power rails.
Interface SPI SPI Both use SPI, so the same host microcontroller bus type can be reused.
Integrated features Internal reference, oscillator, lead-off detection, respiration measurement, Wilson terminal Internal reference, oscillator, PGA, IDAC current sources, GPIO On-chip features reduce external component count and board area for the target application.
Package 64-TQFP (10x10) 64-TQFP (10x10) Identical package footprint allows potential drop-in board layout reuse.
Operating temperature range -40 °C to +85 °C -40 °C to +125 °C Wider temperature range supports use in harsher industrial environments.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS114S08IPBS ADS1198CPAG
Part Status Active Active
Number of Bits 16 16
Sampling Rate(Per Second) 4k -
Number of Inputs 12 -
Input Type Differential, Pseudo-Differential, Single Ended -
Data Interface SPI -
Configuration MUX-PGA-ADC -
Number of A/D Converters 1 -
Architecture Sigma-Delta -
Reference Type External, Internal -
Voltage - Supply, Analog 2.7V ~ 5.25V 2.7V ~ 5.25V
Voltage - Supply, Digital 2.7V ~ 3.6V 1.65V ~ 3.6V
Features PGA, Temperature Sensor -
Operating Temperature -50°C ~ 125°C -
Number of Channels - 8
Power (Watts) - 8.2 mW
Mounting Type - Surface Mount

Frequently asked questions

What are the primary functional differences between the ADS1198CPAG and the ADS114S08IPBS?

The ADS1198CPAG is an 8-channel, 16-bit delta-sigma analog front-end (AFE) designed for biopotential measurements, integrating programmable gain amplifiers, an internal oscillator, and a respiration impedance measurement block. The ADS114S08IPBS is a 12-channel, 16-bit delta-sigma ADC with a programmable gain amplifier and an integrated reference, intended for general-purpose precision sensor measurement. The ADS1198CPAG targets ECG/EEG and similar medical instrumentation, while the ADS114S08IPBS targets general precision signal acquisition.

Are the ADS1198CPAG and ADS114S08IPBS pin-to-pin or package compatible?

No. The ADS1198CPAG is supplied in a 64-pin TQFP (PAG suffix) package, while the ADS114S08IPBS is supplied in a 32-pin TQFP (PBS suffix) package. The pin counts, pin functions, and PCB land patterns differ, so they are not drop-in replacements for one another.

How do the input channel counts and data rates compare?

The ADS1198CPAG provides 8 differential input channels with a maximum data rate of 8 kSPS per channel. The ADS114S08IPBS provides 12 single-ended or 6 differential inputs and supports data rates up to 2 kSPS. The channel count and throughput requirements of the target design should be evaluated against these figures.

Do both devices include an integrated voltage reference?

The ADS114S08IPBS integrates an internal voltage reference. The ADS1198CPAG does not include an internal voltage reference and requires an external reference for its conversions. Designs migrating between the two must account for this difference in external component count and reference accuracy budgeting.

What are the supply voltage requirements for each device?

The ADS1198CPAG operates from an analog supply (AVDD) of 2.7 V to 5.25 V and a digital supply (DVDD) of 1.7 V to 3.6 V. The ADS114S08IPBS operates from an analog supply of 2.7 V to 5.25 V and a digital supply of 2.7 V to 3.6 V. Both are low-voltage CMOS devices, but the digital supply ranges differ, which affects logic-level interfacing.

Is the ADS1198CPAG suitable for general-purpose precision ADC applications like the ADS114S08IPBS?

The ADS1198CPAG is optimized for biopotential AFE applications and includes application-specific features such as respiration impedance measurement and lead-off detection. The ADS114S08IPBS is a general-purpose precision ADC with an integrated reference and a higher channel count. Selection should be based on whether the application requires the specialized biopotential features of the ADS1198CPAG or the general-purpose flexibility of the ADS114S08IPBS.

What are the operating temperature ranges for these two devices?

Both the ADS1198CPAG and the ADS114S08IPBS are specified for operation over the industrial temperature range of -40°C to +85°C. Thermal design and derating should still be validated for the specific application environment.