ADS1220IPW vs ADS1282IPWR

Dieser detaillierte Vergleich von ADS1220IPW und ADS1282IPWR bietet wertvolle Einblicke in deren Spezifikationen und Hauptmerkmale. Wir gehen ausführlich auf wichtige Faktoren ein, darunter RoHS-Konformität, REACH-Status, Serie, Montageart, Gehäusetyp und weitere relevante Eigenschaften. Die übersichtliche Darstellung der Unterschiede vereinfacht die Komponentenauswahl und erleichtert Ihnen die Wahl der optimalen Lösung für Ihre Anwendung.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1282IPWR and ADS1220IPW are both 24-bit delta-sigma ADCs, but they differ fundamentally in resolution architecture, input channel configuration, interface protocol, and package footprint. The ADS1282IPWR is a single-channel, high-resolution seismic-grade converter with a SPI-compatible serial interface in a TSSOP-28 package, while the ADS1220IPW is a four-channel, low-power, PGA-integrated converter with an SPI interface in a TSSOP-16 package. These differences in channel count, footprint, and target application domain prevent direct substitution without board redesign and firmware adaptation.

Different channel count Different footprint Different interface protocol Different input architecture

Parts at a glance

Part A

ADS1220IPW

Texas Instruments

Lifecycle
Active
Stock
4062 Stückzahl
Package
TSSOP-16
Series
Datenerfassung mit Analog to Digital Converters (ADC)
Part B

ADS1282IPWR

Texas Instruments

Lifecycle
Active
Stock
3098 Stückzahl
Package
TSSOP-28
Series
Datenerfassung mit Analog to Digital Converters (ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1282IPWR ADS1220IPW Why it matters
Resolution (bits) 31 24 Higher resolution enables detection of smaller signal changes, which is critical for precision measurement and seismic/energy exploration applications.
Number of input channels 2 (differential) 4 (2 differential / 4 single-ended) More channels allow measurement of additional sensors without adding external multiplexers, affecting system complexity and cost.
Maximum sample rate 4 kSPS 2 kSPS Sample rate determines the bandwidth of signals that can be captured; higher rates suit faster-changing inputs.
Interface type SPI SPI Both use SPI, so the host microcontroller interface is compatible, easing drop-in substitution at the digital level.
PGA / gain stage No integrated PGA (external gain) Integrated PGA (gain 1 to 128) An integrated PGA allows direct amplification of low-level sensor signals, reducing external component count and board space.
Supply voltage 5 V analog (2.5 V digital) 2.7 V to 5.5 V (single supply) Supply requirements affect power rail design and compatibility with low-voltage systems; the ADS1220 offers wider single-supply flexibility.
Package TSSOP-28 TSSOP-16 Different package footprints and pin counts require PCB layout changes, preventing direct drop-in replacement.
Operating temperature range -40 °C to +85 °C -40 °C to +125 °C A wider temperature range supports harsher environments such as industrial and automotive applications.
Typical application focus Seismic and energy exploration, high-resolution measurement Precision sensor measurement, portable instrumentation Application focus indicates the intended signal chain and helps assess whether the part meets system-level performance needs.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1220IPW ADS1282IPWR
Part Status Active Active
Number of Bits 24 31
Sampling Rate(Per Second) 2k 4k
Number of Inputs 2, 4 1
Input Type Differential, Single Ended Differential
Data Interface SPI SPI
Configuration MUX-PGA-ADC ADC
Number of A/D Converters 1 1
Architecture Sigma-Delta Sigma-Delta
Reference Type External, Internal, Supply External
Voltage - Supply, Analog 2.3V ~ 5.5V, ±2.5 5V
Voltage - Supply, Digital 2.3V ~ 5.5V 1.65V ~ 3.6V
Features PGA, Temperature Sensor PGA
Operating Temperature -40°C ~ 125°C -40°C ~ 85°C

Frequently asked questions

What are the primary differences between the ADS1282IPWR and ADS1220IPW?

The ADS1282IPWR is a 31-bit delta-sigma ADC with a maximum data rate of 4 kSPS, designed for seismic and high-resolution energy exploration applications, featuring a programmable gain amplifier (PGA) with gains of 1, 2, 4, 8, and 64. The ADS1220IPW is a 24-bit delta-sigma ADC with a maximum data rate of 2 kSPS, offering a PGA with gains of 1 to 128 and integrated features such as a voltage reference, oscillator, and SPI interface, targeting general-purpose sensor measurement applications.

Are the ADS1282IPWR and ADS1220IPW pin-to-pin compatible?

No. The ADS1282IPWR is supplied in a TSSOP-28 package, while the ADS1220IPW is supplied in a TSSOP-16 package. The different pin counts and pin functions prevent direct PCB footprint compatibility between the two devices.

What are the resolution and data rate specifications of each device?

The ADS1282IPWR provides 31-bit resolution with a maximum output data rate of 4 kSPS. The ADS1220IPW provides 24-bit resolution with a maximum output data rate of 2 kSPS. Both are delta-sigma ADCs, but the ADS1282IPWR targets higher resolution and faster throughput for demanding precision applications.

How do the PGA gain ranges compare between the ADS1282IPWR and ADS1220IPW?

The ADS1282IPWR integrates a PGA with selectable gains of 1, 2, 4, 8, and 64. The ADS1220IPW integrates a PGA with selectable gains of 1, 2, 4, 8, 16, 32, 64, and 128. The ADS1220IPW offers a wider gain range, making it suitable for lower-amplitude sensor signals, while the ADS1282IPWR focuses on high-resolution acquisition with moderate gain settings.

Do both devices include an integrated voltage reference?

No. The ADS1220IPW includes an integrated 2.048 V voltage reference, along with an internal oscillator and SPI interface, reducing external component count. The ADS1282IPWR does not include an integrated voltage reference and requires an external reference for operation, which allows the designer to select a reference optimized for the target measurement accuracy.

What are the typical target applications for each ADC?

The ADS1282IPWR is designed for high-resolution seismic data acquisition, energy exploration, and precision industrial measurement where 31-bit resolution and low noise are critical. The ADS1220IPW is intended for general-purpose sensor measurement, portable instrumentation, temperature and pressure sensing, and other applications requiring a compact 24-bit ADC with integrated reference and oscillator.

What supply voltage ranges do the ADS1282IPWR and ADS1220IPW support?

The ADS1282IPWR operates from an analog supply of 5 V (with a digital supply of 1.8 V to 3.3 V) and supports bipolar analog inputs. The ADS1220IPW operates from a single supply of 2.7 V to 5.5 V (or dual supplies of ±2.5 V) and supports both single-ended and differential inputs. Designers should verify exact supply and input range requirements against the respective manufacturer datasheets.

Can the ADS1220IPW be used as a drop-in replacement for the ADS1282IPWR in an existing design?

No. The devices differ in package (TSSOP-16 vs TSSOP-28), resolution (24-bit vs 31-bit), maximum data rate (2 kSPS vs 4 kSPS), PGA gain options, and integrated features such as the voltage reference. A direct drop-in replacement is not possible; any substitution requires a full review of schematic, layout, and firmware changes against the manufacturer datasheets.