MAX828EUK vs MAX821LUS/GG8

Dieser detaillierte Vergleich von MAX828EUK und MAX821LUS/GG8 bietet wertvolle Einblicke in deren Spezifikationen und Hauptmerkmale. Wir gehen ausführlich auf wichtige Faktoren ein, darunter RoHS-Konformität, REACH-Status, Serie, Montageart, Gehäusetyp und weitere relevante Eigenschaften. Die übersichtliche Darstellung der Unterschiede vereinfacht die Komponentenauswahl und erleichtert Ihnen die Wahl der optimalen Lösung für Ihre Anwendung.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The MAX828EUK and MAX821LUS/GG8 are not functionally interchangeable. The MAX828EUK is a switched-capacitor voltage inverter in a 5-pin SOT-23 package, while the MAX821LUS/GG8 is a microprocessor supervisory circuit in a 4-pin SOT-143 package. They differ in function, pinout, package, and electrical characteristics, so direct substitution is not possible without circuit redesign.

Different function Different package Different pinout Different supply voltage

Parts at a glance

Part A

MAX828EUK

Onsemi

Lifecycle
Active
Stock
4366 Stückzahl
Package
SOT-23-5
Series
PMIC Frequenzregler für Spannungsregler und DC DC Schaltregler
Part B

MAX821LUS/GG8

Analog Devices Inc./Maxim Integrated

Lifecycle
Active
Stock
4512 Stückzahl
Package
SOT-23-4
Series
PMIC-Kontrolleure

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter MAX828EUK MAX821LUS/GG8 Why it matters
Function Switched-capacitor voltage inverter (charge pump) Voltage monitor / supervisory circuit These devices perform fundamentally different functions, so they are not functionally substitutable in most designs.
Output Type Negative voltage output (inverting charge pump) Open-drain reset/monitor output The output signal type determines how the device interfaces with the rest of the circuit.
Input Voltage Range 1.5 V to 5.5 V 2.0 V to 5.5 V (monitored supply) The usable supply range affects compatibility with the system power rail.
Output Current Capability Up to approximately 50 mA Not applicable (logic output only) Load-driving capability determines whether the part can power downstream circuitry.
Typical Operating Frequency 12 kHz (internal oscillator) Not applicable Switching frequency influences output ripple and required capacitor sizing for the charge pump.
External Components Required Two capacitors (fly and reservoir) None required for basic monitoring External component count affects board area, cost, and design complexity.
Package 5-pin SOT-23 8-pin SOIC (or similar) Package footprint and pin count must match the PCB layout for a drop-in replacement.
Primary Application Generating negative bias rails from a positive supply Supply voltage monitoring and reset generation Intended application defines the role the part plays in the system and whether substitution is feasible.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification MAX828EUK MAX821LUS/GG8
Part Status Obsolete Active
Function Ratiometric -
Output Configuration Negative -
Topology Charge Pump -
Output Type Fixed -
Number of Outputs 1 -
Voltage - Input (Min) 1.5V -
Voltage - Input (Max) 5.5V -
Voltage - Output (Min/Fixed) -Vin, 2Vin -
Current - Output 25mA -
Frequency - Switching 12kHz -
Synchronous Rectifier No -
Operating Temperature -40°C ~ 85°C (TA) -
Mounting Type Surface Mount -

Frequently asked questions

Are the MAX828EUK and MAX821LUS/GG8 interchangeable in a circuit design?

No. The MAX828EUK is a switched-capacitor voltage inverter in a 5-pin SOT-23 package, while the MAX821LUS/GG8 is a microprocessor supervisory circuit in a 4-pin SOT-143 package. They have different functions, pinouts, and electrical characteristics, so they are not interchangeable.

What is the primary function of the MAX828EUK?

The MAX828EUK is a monolithic, CMOS switched-capacitor voltage inverter that converts a positive input voltage to a corresponding negative output voltage. It typically operates from a +1.5 V to +5.5 V input and provides an inverted output with high efficiency.

What is the primary function of the MAX821LUS/GG8?

The MAX821LUS/GG8 is a microprocessor supervisory circuit that monitors the power supply and generates a reset signal for microprocessor systems. It asserts a reset output when the supply voltage falls below a preset threshold, ensuring proper system initialization.

What are the key electrical differences between the MAX828EUK and MAX821LUS/GG8?

The MAX828EUK is a voltage inverter with an output current capability typically up to 20 mA and a switching frequency around 12 kHz. The MAX821LUS/GG8 is a voltage supervisor with a fixed reset threshold (typically 4.63 V for the L version) and a reset timeout period, but it does not invert voltage or source significant load current.

Can the MAX828EUK and MAX821LUS/GG8 operate from the same supply voltage?

The MAX828EUK operates from a supply range of +1.5 V to +5.5 V. The MAX821LUS/GG8 is designed for 5 V systems and monitors a 4.63 V threshold. While both can operate from a 5 V supply, their supply requirements and functions differ, so they are not direct substitutes.

Do the MAX828EUK and MAX821LUS/GG8 have the same package and pinout?

No. The MAX828EUK is offered in a 5-pin SOT-23 package, while the MAX821LUS/GG8 is in a 4-pin SOT-143 package. The pin counts and functions are different, so PCB footprints and connections are not compatible.

Are there any application areas where both the MAX828EUK and MAX821LUS/GG8 could be used together?

Yes. In a system requiring both a negative supply rail and reliable microprocessor reset, the MAX828EUK can generate a negative voltage (e.g., for analog circuitry), while the MAX821LUS/GG8 can supervise the positive supply and reset the processor. They serve complementary roles and can coexist in the same design.