Abbildungen dienen nur als Referenz
AD8495CRMZ
+StücklisteIC THERMOCOUPLE A W/COMP 8MSOP
-
HerstellerAnalog Devices Inc.
-
Herstellerteil #AD8495CRMZ
-
Paket MSOP-8
-
Auf Lager5995
365 Tage Qualitätsgarantie
7*24 Stunden-Servicegarantie
90-Tage Kundendienstgarantie
Originalproduktgarantie
Spezifikationen
| Attribut | Wert |
| Package | Tube |
| ProductStatus | Active |
| Type | Thermocouple Amplifier |
| InputType | Differential |
| OutputType | Analog |
| Current-Supply | 250 µA |
| OperatingTemperature | 0°C ~ 50°C |
| MountingType | Surface Mount |
| Package/Case | 8-TSSOP, 8-MSOP (0.118, 3.00mm Width) |
Übersicht
Description
The device operates over a wide temperature range and delivers a high level of accuracy, making it suitable for various applications, including industrial, automotive, and consumer electronics. It is housed in a small, surface-mount MSOP package, which makes it ideal for space-constrained applications. Additionally, its single-supply operation and low power consumption are advantageous for battery-operated devices. Overall, the AD8495CRMZ simplifies the integration of thermocouples into a system by providing a reliable and efficient means of temperature measurement.
Equivalent
Features
Key features include:
1. High Accuracy: Offers a typical accuracy of ±2°C over a wide temperature range.
2. Wide Operating Range: Supports ambient temperatures from -40°C to +125°C.
3. Integrated Cold Junction Compensation: Simplifies design by compensating for cold junction temperature variations.
4. Low Power Consumption: Consumes minimal power, making it suitable for battery-powered applications.
5. Linear Output: Provides a linear output voltage proportional to the thermocouple temperature, simplifying the conversion to digital temperature values.
6. Single Supply Operation: Operates on a single 3V to 5.25V power supply.
7. Simplicity and Compactness: Reduces the need for calibration and external components, facilitating compact design solutions.
The AD8495CRMZ is suitable for precision temperature measurement in industrial, medical, and consumer applications.
Pinout
1. V+ (Pin 8): Positive power supply input.
2. V- (Pin 4): Negative power supply input or ground.
3. +IN (Pin 1): Positive input for the thermocouple.
4. -IN (Pin 2): Negative input for the thermocouple.
5. REF (Pin 5): Reference voltage input, used to offset the output.
6. OUT (Pin 6): Analog output where the amplified and conditioned thermocouple signal is available.
7. COM (Pin 3): Common or reference node for input and output voltage.
8. NC or DNC (Pin 7): No connection or do not connect; typically used for stability and physical support.
The AD8495CRMZ is often used in applications requiring temperature measurement and signal conditioning due to its integrated cold-junction compensation and linearization functions for thermocouples.