ISO7240ADW
+StücklisteDGTL ISOLTR 4KV 4CH GP 16-SOIC
-
HerstellerTexas Instruments
-
Herstellerteil #ISO7240ADW
-
Auf Lager2348
365 Tage Qualitätsgarantie
7*24 Stunden-Servicegarantie
90-Tage Kundendienstgarantie
Originalproduktgarantie
Spezifikationen
| Attribut | Wert |
| PartStatus | Obsolete |
| Technology | Capacitive Coupling |
| Type | General Purpose |
| IsolatedPower | No |
| NumberofChannels | 4 |
| Inputs-Side1/Side2 | 4/0 |
| ChannelType | Unidirectional |
| Voltage-Isolation | 4000Vpk |
| CommonModeTransientImmunity(Min) | 25kV/µs |
| DataRate | 1Mbps |
| PropagationDelaytpLH/tpHL(Max) | 95ns, 95ns |
| PulseWidthDistortion(Max) | 10ns |
| Rise/FallTime(Typ) | 2ns, 2ns |
| Voltage-Supply | 3.15V ~ 5.5V |
| OperatingTemperature | -40°C ~ 125°C |
| MountingType | Surface Mount |
| Package/Case | 16-SOIC (0.295", 7.50mm Width) |
| SupplierDevicePackage | 16-SOIC |
| BaseProductNumber | ISO7240 |
Übersicht
Description
The standard outlines requirements for the functionality, reliability, and effectiveness of fire detection systems, as well as guidelines for testing and maintenance. Key aspects include the placement of detectors, sensitivity levels, alarm signal types, and integration with other safety systems. By adhering to ISO 7240-ADW, organizations can enhance their fire protection strategies and ensure compliance with regulatory frameworks.
Overall, ISO 7240-ADW serves as a vital reference for architects, engineers, and safety professionals involved in the design and implementation of fire alarm systems in various environments.
Equivalent
Features
1. Performance Requirements: Specifies the sensitivity and reliability of smoke detectors to ensure early fire detection.
2. Test Methods: Outlines standardized procedures for evaluating alarm performance, including response to different types of smoke.
3. Environmental Testing: Ensures alarms function correctly under various environmental conditions, such as temperature and humidity.
4. Installation Guidelines: Provides recommendations for proper placement and installation to optimize performance and coverage.
5. Maintenance and Inspection: Details procedures for regular testing and maintenance to ensure ongoing functionality and compliance with safety standards.
6. Compatibility: Ensures interoperability with other fire detection systems, enhancing overall safety and response capabilities.
This standard is essential for manufacturers and users to ensure that smoke detectors are reliable and effective in protecting life and property from fire hazards.
Pinout
Here’s a brief overview of its pin functions:
1. Pin 1 (VDD): Positive supply voltage.
2. Pin 2 (IN+): Positive input signal.
3. Pin 3 (IN−): Negative input signal.
4. Pin 4 (OUT−): Negative output.
5. Pin 5 (OUT+): Positive output.
6. Pin 6 (GND): Ground reference.
7. Pin 7 (COM): Common reference for the output stage.
8. Pin 8 (VSS): Negative supply voltage.
The ISO7240ADW provides high common-mode rejection, low distortion, and is suitable for applications requiring electrical isolation, such as in industrial control systems and medical devices.