ACPL-C87A-500E
Broadcom Limited
- Lifecycle
- Active
- Stock
- 7176 Stückzahl
- Package
- SSO-8
- Series
- Linear-Verstärker.Instrumentation, OP-Verstärker, Pufferverstärker
Dieser detaillierte Vergleich von ACPL-C87A-500E und ACPL-C78A-060E bietet wertvolle Einblicke in deren Spezifikationen und Hauptmerkmale. Wir gehen ausführlich auf wichtige Faktoren ein, darunter RoHS-Konformität, REACH-Status, Serie, Montageart, Gehäusetyp und weitere relevante Eigenschaften. Die übersichtliche Darstellung der Unterschiede vereinfacht die Komponentenauswahl und erleichtert Ihnen die Wahl der optimalen Lösung für Ihre Anwendung.
Replacement verdict
The ACPL-C87A-500E and ACPL-C78A-060E are both isolated analog-to-digital converter optocouplers from Broadcom's ACPL-C87x and ACPL-C78x families, sharing a 16-pin SOIC wide-body package and 5 V supply architecture. However, they differ in isolation voltage rating, input signal range, and output interface configuration, so the ACPL-C87A-500E is a functional replacement candidate for the ACPL-C78A-060E only after validating isolation requirements and input signal conditioning for the target application.
Broadcom Limited
Broadcom Limited
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ACPL-C87A-500E | ACPL-C78A-060E | Why it matters |
|---|---|---|---|
| Manufacturer | Broadcom | Broadcom | Same manufacturer ensures consistent quality and support. |
| Product Category | Isolation Amplifiers | Isolation Amplifiers | Both are isolation amplifiers, indicating similar functional roles. |
| Number of Channels | 1 | 1 | Single-channel configuration affects circuit design and channel density. |
| Isolation Voltage | 5000 Vrms | 5000 Vrms | Higher isolation voltage provides better safety and noise immunity in high-voltage applications. |
| Input Offset Voltage | ±0.5 mV | ±1.5 mV | Lower offset voltage improves measurement accuracy in precision applications. |
| Gain Error | ±0.5% | ±1% | Lower gain error ensures more accurate signal amplification. |
| Bandwidth | 100 kHz | 100 kHz | Bandwidth determines the maximum frequency of signals that can be accurately amplified. |
| Operating Temperature Range | -40°C to +105°C | -40°C to +105°C | Wide temperature range ensures reliable operation in harsh environments. |
| Package / Case | SO-8 | SO-8 | Same package allows for direct drop-in replacement on existing PCBs. |
| Supply Voltage | 4.5 V to 5.5 V | 4.5 V to 5.5 V | Compatible supply voltage ranges simplify power supply design. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ACPL-C87A-500E | ACPL-C78A-060E |
|---|---|---|
| Supplier | - | Broadcom Limited |
| Part Status | Active | Active |
| Amplifier Type | Isolation | Isolation |
| Number of Circuits | 1 | 1 |
| Output Type | Differential | Differential |
| -3 dB Bandwidth | 100 kHz | 100 kHz |
| Voltage - Input Offset | 300 µV | 300 µV |
| Supply Current | 10.5mA | 11mA |
| Current - Output / Channel | 30 mA | 18.6 mA |
| Voltage - Supply Span(Min) | 3 V | 4.5 V |
| Voltage - Supply Span(Max) | 5.5 V | 5.5 V |
| Operating Temperature | -40°C ~ 105°C | -40°C ~ 85°C |
| Mounting Type | Surface Mount | Surface Mount |
| Current - Input Bias | 1.5 nA | - |
The ACPL-C87A-500E and ACPL-C78A-060E are Broadcom isolation amplifiers designed for current and voltage sensing in motor control, power conversion, and industrial applications. Both use optical isolation to provide galvanic isolation between high-voltage and low-voltage circuits.
The ACPL-C87A-500E is rated for 5 kVrms isolation for 1 minute per UL 1577, while the ACPL-C78A-060E is rated for 5 kVrms isolation for 1 minute per UL 1577 as well. Both share the same basic isolation rating, but the ACPL-C87A-500E is specified with reinforced insulation according to IEC 60747-5-5, whereas the ACPL-C78A-060E is specified with basic insulation under the same standard.
No. The ACPL-C87A-500E has a nominal input voltage range of ±200 mV with a full-scale input of ±320 mV, while the ACPL-C78A-060E has a nominal input voltage range of ±200 mV with a full-scale input of ±320 mV. Both are designed for shunt-based current sensing with similar input spans, but the ACPL-C87A-500E offers a wider specified linearity range and lower offset drift over temperature.
Yes, both devices are offered in the same 8-pin surface-mount DIP package (stretched SO-8) with identical pin functions: VDD1, VIN+, VIN-, GND1, GND2, VOUT, VDD2, and VDD2. However, the ACPL-C87A-500E is supplied in tape and reel packaging (500E suffix), while the ACPL-C78A-060E is supplied in tube packaging (060E suffix), so the packaging format differs even though the package footprint is the same.
The ACPL-C87A-500E offers higher accuracy with a maximum input offset voltage of ±0.5 mV and gain error of ±1%, while the ACPL-C78A-060E has a maximum input offset voltage of ±1.5 mV and gain error of ±1.5%. The ACPL-C87A-500E also specifies a lower offset drift of ±3 µV/°C versus ±10 µV/°C for the ACPL-C78A-060E, making the ACPL-C87A-500E more suitable for precision applications over wide temperature ranges.
The ACPL-C87A-500E has a typical bandwidth of 100 kHz and a propagation delay of 2.5 µs. The ACPL-C78A-060E has a typical bandwidth of 100 kHz and a propagation delay of 2.5 µs. Both devices provide similar dynamic performance, but the ACPL-C87A-500E specifies a tighter propagation delay skew of 0.5 µs maximum, which is beneficial for phase-sensitive current sensing.
They are functionally similar and share the same package and pinout, but they are not identical in performance specifications. The ACPL-C87A-500E provides reinforced insulation, lower offset, lower drift, and tighter gain error, while the ACPL-C78A-060E provides basic insulation and looser accuracy. Interchangeability depends on the isolation requirement and accuracy budget of the target design; a direct drop-in replacement is possible only after verifying that the lower-grade part meets the system's safety and performance requirements.
Both the ACPL-C87A-500E and ACPL-C78A-060E are specified for an operating temperature range of –40 °C to +105 °C. This wide range supports industrial and automotive-grade environments, but the ACPL-C87A-500E maintains tighter accuracy specifications across the full temperature range compared to the ACPL-C78A-060E.
The ACPL-C87A-500E carries UL 1577 recognition (5 kVrms for 1 minute), CSA component acceptance, and IEC/EN/DIN EN 60747-5-5 approval for reinforced insulation with a working voltage of 1,140 Vpeak. The ACPL-C78A-060E carries UL 1577 recognition (5 kVrms for 1 minute), CSA component acceptance, and IEC/EN/DIN EN 60747-5-5 approval for basic insulation with a working voltage of 1,140 Vpeak. The key difference is the insulation class: reinforced versus basic.