Dieser detaillierte Vergleich von ACS723LLCTR-20AU-T und ACS723LLCTR-05AB-T bietet wertvolle Einblicke in deren Spezifikationen und Hauptmerkmale. Wir gehen ausführlich auf wichtige Faktoren ein, darunter RoHS-Konformität, REACH-Status, Serie, Montageart, Gehäusetyp und weitere relevante Eigenschaften. Die übersichtliche Darstellung der Unterschiede vereinfacht die Komponentenauswahl und erleichtert Ihnen die Wahl der optimalen Lösung für Ihre Anwendung.
Replacement verdict
The ACS723LLCTR-05AB-T and ACS723LLCTR-20AU-T are not functionally interchangeable despite sharing the ACS723 family platform. The 05AB variant provides a bidirectional ±5 A sensing range with analog voltage output, while the 20AU variant offers a unidirectional 20 A sensing range with the same analog output topology. The primary incompatibility stems from differing current sensing ranges and directionality, which directly affect measurement accuracy, full-scale output voltage, and application suitability. Designers must verify whether their target application requires bidirectional or unidirectional current sensing and confirm the appropriate measurement range before considering either device as a substitute.
Allegro MicroSystems
Allegro MicroSystems
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ACS723LLCTR-05AB-T | ACS723LLCTR-20AU-T | Why it matters |
|---|---|---|---|
| Current Sensing Range | ±5 A | ±20 A | Defines the maximum measurable current; a 20 A part cannot be substituted where 5 A full-scale resolution is required, and vice versa. |
| Sensitivity | 400 mV/A | 100 mV/A | Determines output voltage per amp of sensed current; different sensitivity changes the ADC scaling and measurement resolution in the application. |
| Output Type | Analog, bidirectional | Analog, unidirectional | Bidirectional parts sense both positive and negative current, while unidirectional parts only sense one polarity, affecting circuit topology and signal conditioning. |
| Supply Voltage | 4.5 V to 5.5 V | 4.5 V to 5.5 V | Both devices operate from the same 5 V nominal rail, so power supply design is compatible between the two parts. |
| Isolation Voltage | 2.1 kVrms | 2.1 kVrms | Rated isolation between the current path and signal side is identical, so safety and creepage requirements are met by either part. |
| Bandwidth | 80 kHz | 80 kHz | Same signal bandwidth means both parts respond equally fast to current transients, preserving dynamic performance. |
| Operating Temperature Range | -40 °C to 150 °C | -40 °C to 150 °C | Identical temperature ratings ensure both parts are suitable for the same industrial and automotive environments. |
| Package | 8-lead SOIC | 8-lead SOIC | Same footprint and pinout allow drop-in PCB compatibility without layout changes. |
| Typical Accuracy / Total Error | ±3% typical | ±3% typical | Accuracy is comparable, but the different full-scale range means absolute error in amps differs significantly between the two parts. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ACS723LLCTR-20AU-T | ACS723LLCTR-05AB-T |
|---|---|---|
| Part Status | Active | Active |
| For Measuring | AC/DC | AC/DC |
| Sensor Type | Hall Effect, Open Loop | Hall Effect, Open Loop |
| Current - Sensing | 20A | 5A |
| Number of Channels | 1 | 1 |
| Output | Ratiometric, Voltage | Ratiometric, Voltage |
| Sensitivity | 200mv/A | 400mV/A |
| Frequency | DC ~ 80kHz | DC ~ 80kHz |
| Linearity | ±1% | ±1% |
| Accuracy | ±3% | ±3% |
| Voltage - Supply | 5V | 5V |
| Response Time | 5µs | 5µs |
| Current - Supply (Max) | 14mA | 14mA |
| Operating Temperature | -40°C ~ 150°C | -40°C ~ 150°C |
| Polarization | Unidirectional | Bidirectional |
| Mounting Type | Surface Mount | Surface Mount |
The ACS723LLCTR-05AB-T is a bidirectional current sensor with a primary sensed current range of ±5 A and a nominal sensitivity of 400 mV/A. The ACS723LLCTR-20AU-T is a unidirectional current sensor with a primary sensed current range of 0 to 20 A and a nominal sensitivity of 100 mV/A. Both are galvanically isolated, factory-trimmed, and housed in the same SOIC-8 package.
Yes. Both devices are offered in the same 8-lead SOIC package with identical pinouts, allowing them to share a common PCB footprint. However, pin compatibility does not guarantee functional interchangeability without validating the measurement range, sensitivity, and directionality requirements of the target application.
No, they are not directly interchangeable. The ACS723LLCTR-05AB-T measures bidirectional currents up to ±5 A with 400 mV/A sensitivity, while the ACS723LLCTR-20AU-T measures unidirectional currents up to 20 A with 100 mV/A sensitivity. Substitution requires verifying the current range, directionality, output voltage swing, and ADC resolution of the host system.
Both devices operate from a single 5 V supply and provide basic isolation rated for 2.4 kVRMS (UL 60950-1) between the primary current path and the low-voltage signal side. These ratings are common to the ACS723 family and are specified in the Allegro MicroSystems datasheet.
The choice depends on the current magnitude and direction. The ACS723LLCTR-05AB-T is suited for low-current bidirectional monitoring such as charge and discharge currents in small battery packs. The ACS723LLCTR-20AU-T is suited for higher unidirectional currents, such as discharge-only monitoring in higher-power battery systems. Neither device is universally better; selection must match the application's current profile.
The ACS723LLCTR-05AB-T has a nominal sensitivity of 400 mV/A with a quiescent output of VCC/2, producing an output swing of approximately 0.5 V to 4.5 V over ±5 A. The ACS723LLCTR-20AU-T has a nominal sensitivity of 100 mV/A with a quiescent output of approximately 0.5 V, producing an output swing of approximately 0.5 V to 4.5 V over 0 to 20 A. Exact limits should be confirmed from the Allegro datasheet.
Both devices are specified for an operating temperature range of -40 °C to +125 °C and are factory-trimmed for accuracy. However, total output error, nonlinearity, and thermal drift may differ between the ±5 A bidirectional and 0 to 20 A unidirectional variants. Designers should consult the respective datasheet sections for exact error budgets rather than assuming identical accuracy performance.
The ACS723LLCTR-05AB-T is typically used in bidirectional current sensing applications such as motor control, power inverters, and battery charge/discharge monitoring where currents do not exceed ±5 A. The ACS723LLCTR-20AU-T is typically used in unidirectional high-current applications such as DC-DC converter output monitoring, load current sensing, and power supply overcurrent detection up to 20 A.