AD8495CRMZ vs AD8494CRMZ

Dieser detaillierte Vergleich von AD8495CRMZ und AD8494CRMZ bietet wertvolle Einblicke in deren Spezifikationen und Hauptmerkmale. Wir gehen ausführlich auf wichtige Faktoren ein, darunter RoHS-Konformität, REACH-Status, Serie, Montageart, Gehäusetyp und weitere relevante Eigenschaften. Die übersichtliche Darstellung der Unterschiede vereinfacht die Komponentenauswahl und erleichtert Ihnen die Wahl der optimalen Lösung für Ihre Anwendung.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Compatible functional replacement candidate

The AD8495CRMZ and AD8494CRMZ are functionally interchangeable thermocouple amplifier candidates, sharing the same package, supply range, and output configuration, with the primary distinction being the factory-set thermocouple type and corresponding temperature range. Designers should confirm the intended thermocouple type and calibration before substituting one for the other in a given application.

Package Type High match
Output Type High match
Supply Voltage Range High match
Thermocouple Type and Temperature Range Validation required

Parts at a glance

Part A

AD8495CRMZ

Analog Devices Inc.

Lifecycle
Active
Stock
5995 Stückzahl
Package
MSOP-8
Series
Sensor- und Detektorschnittstellen
Part B

AD8494CRMZ

Analog Devices Inc.

Lifecycle
Active
Stock
7989 Stückzahl
Package
TSSOP-8
Series
Sensor- und Detektorschnittstellen

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter AD8495CRMZ AD8494CRMZ Why it matters
Sensor Type K-Type Thermocouple J-Type Thermocouple Determines which thermocouple the amplifier is calibrated for; using the wrong type produces incorrect temperature readings.
Output Voltage at 25°C (Ambient) 5.0 mV/°C × 25°C = 125 mV (K-type, 41 µV/°C) 5.0 mV/°C × 25°C = 125 mV (J-type, 52 µV/°C) The output scaling differs because the internal gain is set for the specific thermocouple sensitivity; the transfer function is not interchangeable.
Thermocouple Sensitivity (Seebeck Coefficient) ~41 µV/°C (K-type) ~52 µV/°C (J-type) The amplifier gain is factory-trimmed to the thermocouple's Seebeck coefficient, so the two parts are not functionally substitutable.
Temperature Range (Typical) 0°C to +50°C reference, thermocouple range up to ~+1000°C (K-type) 0°C to +50°C reference, thermocouple range up to ~+750°C (J-type) The usable measurement range depends on the thermocouple type; J-type has a lower maximum temperature than K-type.
Supply Voltage Range 2.7 V to 18 V (single supply) 2.7 V to 18 V (single supply) Both parts share the same supply requirements, so power supply design is identical.
Supply Current (Typical) ~180 µA ~180 µA Identical quiescent current means no change in power budget when substituting.
Package 8-Lead MSOP (RMZ) 8-Lead MSOP (RMZ) Same footprint and pinout allow drop-in PCB compatibility.
Operating Temperature Range −40°C to +125°C −40°C to +125°C Identical industrial temperature rating ensures equivalent environmental robustness.
Output Type Analog voltage output (ratiometric to temperature) Analog voltage output (ratiometric to temperature) Both provide the same analog interface style, simplifying downstream ADC design.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification AD8495CRMZ AD8494CRMZ
Supplier - Analog Devices Inc.
Part Status Active Active
Type Thermocouple Amplifier Thermocouple Amplifier
Input Type Differential Differential
Output Type Analog Analog
Supply Current 250 µA 250 µA
Operating Temperature 0°C ~ 50°C 0°C ~ 50°C
Mounting Type Surface Mount Surface Mount

Frequently asked questions

What is the primary functional difference between the AD8495CRMZ and the AD8494CRMZ?

Both are thermocouple amplifiers with cold junction compensation, but they are optimized for different thermocouple types. The AD8495CRMZ is calibrated for Type K thermocouples, providing a 5 mV/°C output, while the AD8494CRMZ is calibrated for Type J thermocouples, providing a 5 mV/°C output with a different internal cold junction compensation curve.

Are the AD8495CRMZ and AD8494CRMZ pin-compatible?

Yes. Both devices are offered in the same 8-lead MSOP (RM) package and share an identical pinout, allowing them to be used interchangeably on the same PCB layout when the thermocouple type and compensation are adjusted accordingly.

What is the output voltage range and supply requirement for these devices?

Both the AD8495CRMZ and AD8494CRMZ operate from a single supply of 2.7 V to 18 V (or dual supplies) and provide a rail-to-rail output voltage that is proportional to the thermocouple temperature at 5 mV/°C, referenced to the supply midpoint or a defined reference pin.

Can the AD8495CRMZ be used with a Type J thermocouple?

No. The AD8495CRMZ contains cold junction compensation and linearization optimized specifically for Type K thermocouples. Using it with a Type J thermocouple would produce inaccurate temperature readings because the compensation curve and sensitivity coefficients differ from the AD8494CRMZ.

What is the operating temperature range for the AD8495CRMZ and AD8494CRMZ?

Both devices are specified for the industrial temperature range of −40°C to +125°C, making them suitable for harsh-environment thermocouple measurement applications.

Do these amplifiers include cold junction compensation?

Yes. Both the AD8495CRMZ and AD8494CRMZ integrate cold junction compensation circuitry and a thermocouple linearization network on-chip, eliminating the need for external compensation components and simplifying thermocouple signal conditioning design.

What package type do the AD8495CRMZ and AD8494CRMZ use?

Both parts are supplied in an 8-lead MSOP (Mini Small Outline Package) designated by the "RM" suffix in the part number, and they are RoHS-compliant.