ADA4062-2ARZ vs ADA4004-4ARZ-RL

Dieser detaillierte Vergleich von ADA4062-2ARZ und ADA4004-4ARZ-RL bietet wertvolle Einblicke in deren Spezifikationen und Hauptmerkmale. Wir gehen ausführlich auf wichtige Faktoren ein, darunter RoHS-Konformität, REACH-Status, Serie, Montageart, Gehäusetyp und weitere relevante Eigenschaften. Die übersichtliche Darstellung der Unterschiede vereinfacht die Komponentenauswahl und erleichtert Ihnen die Wahl der optimalen Lösung für Ihre Anwendung.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADA4062-2ARZ and ADA4004-4ARZ-RL differ in channel count, package footprint, supply voltage range, and quiescent current, so the ADA4004-4ARZ-RL cannot serve as a direct drop-in substitute for the ADA4062-2ARZ without circuit and layout redesign.

Different channel count Different package footprint Different supply voltage range Different quiescent current

Parts at a glance

Part A

ADA4062-2ARZ

Analog Devices Inc.

Lifecycle
Active
Stock
6529 Stückzahl
Package
SOIC-8
Series
Linear-Verstärker.Instrumentation, OP-Verstärker, Pufferverstärker
Part B

ADA4004-4ARZ-RL

Analog Devices Inc.

Lifecycle
Active
Stock
8634 Stückzahl
Package
SOIC-14
Series
Linear-Verstärker.Instrumentation, OP-Verstärker, Pufferverstärker

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADA4062-2ARZ ADA4004-4ARZ-RL Why it matters
Number of Amplifiers 2 4 Determines how many independent signal channels are available in a single package; a direct constraint on circuit topology and board layout.
Input Offset Voltage (max) 250 µV 125 µV Lower offset voltage improves DC accuracy and reduces output error in precision signal-conditioning applications.
Input Bias Current (typ) 0.5 pA 40 nA Very low bias current is critical for high-impedance sensor interfaces and precision integrators; a large difference affects input loading and error.
Gain Bandwidth Product 1.4 MHz 12 MHz Sets the achievable closed-loop bandwidth and speed; a much higher GBW enables faster signal processing and wider-bandwidth filters.
Slew Rate 0.5 V/µs 2.8 V/µs Limits large-signal transient response and full-power bandwidth; higher slew rate supports faster, larger output swings without distortion.
Supply Voltage Range ±5 V to ±15 V (10 V to 30 V) ±5 V to ±15 V (10 V to 30 V) Defines compatibility with the system power rails; matching ranges allow drop-in use in the same supply environment.
Input Voltage Noise Density (1 kHz) 36 nV/√Hz 6 nV/√Hz Lower voltage noise improves SNR in low-level signal amplification; a significant difference affects precision and dynamic range.
Quiescent Current per Amplifier (typ) 0.2 mA 1.7 mA Affects total power consumption and thermal budget; lower quiescent current is preferred for battery-powered or power-sensitive designs.
Package 8-Lead SOIC 14-Lead SOIC Footprint and pin count must match the PCB layout; different packages require board redesign and cannot be directly substituted.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADA4062-2ARZ ADA4004-4ARZ-RL
Supplier - Analog Devices Inc.,Rochester Electronics, LLC
Series - iPolar®
Part Status Active Active
Amplifier Type J-FET General Purpose
Number of Circuits 2 4
Slew Rate 3.3V/µs 2.7V/µs
Gain Bandwidth Product 1.4 MHz 12 MHz
Current - Input Bias 2 pA 40 nA
Voltage - Input Offset 750 µV 40 µV
Current - Output / Channel 20 mA 10 mA
Voltage - Supply Span(Min) 8 V 10 V
Voltage - Supply Span(Max) 36 V 30 V
Operating Temperature -40°C ~ 125°C -40°C ~ 125°C
Mounting Type Surface Mount Surface Mount
Supply Current 165µA (x2 Channels) -

Frequently asked questions

What are the primary differences between the ADA4062-2ARZ and the ADA4004-4ARZ-RL?

The ADA4062-2ARZ is a dual-channel, low-power JFET-input operational amplifier, while the ADA4004-4ARZ-RL is a quad-channel, precision bipolar-input operational amplifier. The ADA4062-2ARZ is optimized for low input bias current and low power consumption, whereas the ADA4004-4ARZ-RL is optimized for very low offset voltage, low offset voltage drift, and low voltage noise.

How do the input bias currents of the ADA4062-2ARZ and ADA4004-4ARZ-RL compare?

The ADA4062-2ARZ, with its JFET input stage, features extremely low input bias current, typically in the picoampere range. The ADA4004-4ARZ-RL, using a bipolar input stage, has a higher input bias current, typically in the nanoampere range. The ADA4062-2ARZ is therefore preferable for high-impedance source applications.

Which device offers lower offset voltage and offset voltage drift?

The ADA4004-4ARZ-RL is a precision bipolar op amp with a very low typical offset voltage and low offset voltage drift, making it suitable for DC precision applications. The ADA4062-2ARZ has a higher offset voltage and drift specification than the ADA4004-4ARZ-RL. For applications requiring tight DC accuracy over temperature, the ADA4004-4ARZ-RL is the more appropriate choice.

How do the packages and channel counts differ between these two parts?

The ADA4062-2ARZ is a dual op amp supplied in an 8-lead SOIC package. The ADA4004-4ARZ-RL is a quad op amp supplied in a 14-lead SOIC package. The different channel counts and pin counts mean the two devices are not pin-compatible and cannot be dropped into the same PCB footprint.

Which part is better suited for low-power, high-impedance sensor interfaces?

The ADA4062-2ARZ is generally better suited for low-power, high-impedance sensor interfaces because its JFET input stage provides very low input bias current and its supply current per amplifier is low. The ADA4004-4ARZ-RL, while more precise in DC terms, draws more supply current per amplifier and has higher input bias current, which can introduce errors with high-impedance sources.

Can the ADA4062-2ARZ and ADA4004-4ARZ-RL be used interchangeably in an existing design?

No. The two devices differ in channel count (dual versus quad), package pin count (8-lead versus 14-lead SOIC), input stage type (JFET versus bipolar), and key specifications such as input bias current, offset voltage, and supply current. A direct substitution is not possible without redesigning the PCB footprint and revalidating the circuit against the manufacturer datasheets.

How do the supply current requirements of the ADA4062-2ARZ and ADA4004-4ARZ-RL compare?

The ADA4062-2ARZ is a low-power dual op amp with a low supply current per amplifier, making it suitable for battery-powered and portable applications. The ADA4004-4ARZ-RL is a quad precision op amp that draws more supply current per amplifier. For strict power budgets, the ADA4062-2ARZ is the lower-power option, though the total channel count difference must also be considered.

Which device is more suitable for precision DC instrumentation applications?

The ADA4004-4ARZ-RL is more suitable for precision DC instrumentation because of its low offset voltage, low offset voltage drift, and low voltage noise, which are characteristic of its precision bipolar design. The ADA4062-2ARZ is better suited to applications prioritizing low input bias current and low power rather than tight DC offset performance.