ADS1271IBPWR vs ADS1282HIPW

Dieser detaillierte Vergleich von ADS1271IBPWR und ADS1282HIPW bietet wertvolle Einblicke in deren Spezifikationen und Hauptmerkmale. Wir gehen ausführlich auf wichtige Faktoren ein, darunter RoHS-Konformität, REACH-Status, Serie, Montageart, Gehäusetyp und weitere relevante Eigenschaften. Die übersichtliche Darstellung der Unterschiede vereinfacht die Komponentenauswahl und erleichtert Ihnen die Wahl der optimalen Lösung für Ihre Anwendung.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1271IBPWR and ADS1282HIPW are both 24-bit delta-sigma ADCs in a TSSOP-28 package, but they differ fundamentally in resolution architecture, input configuration, and target application. The ADS1271IBPWR is a single-channel wide-bandwidth converter with a fixed data rate up to 105 kSPS, while the ADS1282HIPW is a dual-channel high-resolution seismic-grade converter with an integrated PGA and data rates up to 4 kSPS. These differences in channel count, programmable gain, and output data rate make the two devices non-interchangeable in existing designs without significant rework.

Different channel count Different data rate Different input configuration Different application class

Parts at a glance

Part A

ADS1271IBPWR

Texas Instruments

Lifecycle
Active
Stock
6728 Stückzahl
Package
TSSOP-16
Series
Datenerfassung mit Analog to Digital Converters (ADC)
Part B

ADS1282HIPW

Texas Instruments

Lifecycle
Active
Stock
6044 Stückzahl
Package
TSSOP-28
Series
Datenerfassung mit Analog to Digital Converters (ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1271IBPWR ADS1282HIPW Why it matters
Resolution (bits) 24 31 Higher resolution enables finer signal detail and lower quantization noise, which is critical for precision measurement and seismic/energy-exploration applications.
Maximum Sample Rate (SPS) 105k 4k Sample rate determines the bandwidth of signals the ADC can capture; the ADS1271 suits wider-bandwidth data acquisition while the ADS1282 targets low-frequency high-precision sensing.
Architecture Delta-Sigma Delta-Sigma Both use delta-sigma conversion, but their differing modulator designs yield very different noise/bandwidth tradeoffs relevant to substitutability.
Number of Input Channels 1 (differential) 2 (differential, multiplexed) Channel count affects how many sensors can be interfaced; the ADS1282 supports two differential inputs while the ADS1271 is single-channel.
Supply Voltage (Analog) 5 V 5 V (analog), 3.3 V (digital) Supply requirements determine power-rail compatibility and whether the part can drop into an existing board design without level shifting.
Interface Type SPI (serial) SPI (serial) Both use SPI, but timing and register maps differ, so firmware and host-controller compatibility must be verified for substitution.
Package TSSOP-16 (PW) TSSOP-28 (PW) Different package footprints and pin counts mean the parts are not drop-in replacements and require PCB layout changes.
Operating Temperature Range -40°C to +105°C -40°C to +85°C Temperature range affects suitability for harsh environments; the ADS1271 offers a wider high-temperature margin.
Typical Power Consumption ~70 mW ~30 mW Power consumption impacts thermal budget and battery life; the ADS1282 is lower power, favoring portable or energy-constrained designs.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1271IBPWR ADS1282HIPW
Supplier - Rochester Electronics, LLC,Texas Instruments
Part Status Active Active
Number of Bits 24 -
Sampling Rate(Per Second) 105k -
Number of Inputs 1 -
Input Type Differential -
Data Interface SPI -
Configuration ADC -
Number of A/D Converters 1 -
Architecture Sigma-Delta -
Reference Type External -
Voltage - Supply, Analog 5V -
Voltage - Supply, Digital 1.65V ~ 3.6V -
Operating Temperature -40°C ~ 105°C -

Frequently asked questions

What are the primary differences between the ADS1271IBPWR and the ADS1282HIPW?

The ADS1271IBPWR is a 24-bit, single-channel delta-sigma ADC with a maximum data rate of 105 kSPS, while the ADS1282HIPW is a 31-bit, single-channel delta-sigma ADC with a maximum data rate of 4 kSPS. The ADS1282HIPW integrates a programmable gain amplifier (PGA) and is designed for high-resolution seismic and energy exploration applications, whereas the ADS1271IBPWR is a wide-bandwidth industrial ADC without an integrated PGA.

Are the ADS1271IBPWR and ADS1282HIPW pin-to-pin compatible?

No. The ADS1271IBPWR is supplied in a 20-pin TSSOP (PW) package, and the ADS1282HIPW is supplied in a 28-pin TSSOP (PW) package. The different pin counts and pin functions prevent direct PCB footprint interchangeability.

Do both ADCs support the same digital interface?

Both devices provide a serial peripheral interface (SPI)-compatible serial output, but the ADS1271IBPWR supports both SPI and frame-sync modes, while the ADS1282HIPW provides a flexible SPI-compatible interface with additional synchronization and calibration command support. The command set and register maps differ between the two devices.

Which device offers higher resolution and lower noise for precision measurement?

The ADS1282HIPW provides 31-bit resolution and is specified for low-noise seismic-grade performance, making it better suited for high-resolution precision measurement. The ADS1271IBPWR provides 24-bit resolution and is intended for wide-bandwidth industrial signal acquisition.

Can the ADS1271IBPWR and ADS1282HIPW operate from the same analog supply voltage?

No. The ADS1271IBPWR operates from a 5 V analog supply (AVDD), while the ADS1282HIPW operates from a 5 V analog supply as well but also requires a separate 3.3 V digital supply (DVDD) and supports a bipolar analog supply configuration. Designers must verify the supply scheme against each datasheet before substitution.

What are the typical target applications for each device?

The ADS1271IBPWR is typically used in industrial measurement, vibration analysis, and wide-bandwidth data acquisition systems. The ADS1282HIPW is typically used in seismic data acquisition, energy exploration, and high-resolution precision instrumentation requiring an integrated PGA.

Do both devices support the same operating temperature range?

Both the ADS1271IBPWR and ADS1282HIPW are specified for the industrial temperature range of -40°C to +85°C, so temperature range alone does not differentiate them for substitution purposes.