AMC1311DWV
Texas Instruments
- Lifecycle
- Active
- Stock
- 6795 Stückzahl
- Package
- SOIC-8
- Series
- Linear-Verstärker
Dieser detaillierte Vergleich von AMC1311DWV und AMC1300DWV bietet wertvolle Einblicke in deren Spezifikationen und Hauptmerkmale. Wir gehen ausführlich auf wichtige Faktoren ein, darunter RoHS-Konformität, REACH-Status, Serie, Montageart, Gehäusetyp und weitere relevante Eigenschaften. Die übersichtliche Darstellung der Unterschiede vereinfacht die Komponentenauswahl und erleichtert Ihnen die Wahl der optimalen Lösung für Ihre Anwendung.
Replacement verdict
The AMC1311DWV and AMC1300DWV share the same isolated amplifier architecture, SOIC-8 (DWV) package, and 5.0 kV reinforced isolation rating, making them strong functional replacement candidates. However, they differ in input voltage range and gain configuration, so the AMC1300DWV is not a direct drop-in substitute for the AMC1311DWV without validating the signal chain against the target application's input span and output scaling requirements.
Texas Instruments
Texas Instruments
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | AMC1311DWV | AMC1300DWV | Why it matters |
|---|---|---|---|
| Input Signal Type | Voltage input (high-impedance, ±1 V range) | Current shunt input (low-impedance, ±250 mV range) | Determines whether the device senses a voltage directly or a shunt resistor voltage drop; these are not functionally interchangeable without external signal conditioning. |
| Input Voltage Range | ±1 V (nominal, high impedance) | ±250 mV (nominal, low impedance) | The full-scale input range dictates the shunt resistor or divider design and directly affects measurement resolution and accuracy. |
| Input Impedance | High (approximately 1 GΩ typical) | Low (approximately 20 kΩ typical) | High input impedance allows direct voltage sensing without loading the source, while low impedance is intended for shunt-based current sensing. |
| Isolation Rating | 5 kV RMS (reinforced) | 5 kV RMS (reinforced) | Both provide the same reinforced galvanic isolation, which is critical for safety and noise immunity in high-voltage systems. |
| Output Interface | Differential analog output | Differential analog output | Identical differential analog output means both interface to the same downstream ADC or amplifier topology. |
| Supply Voltage | 3.0 V to 5.5 V (both sides) | 3.0 V to 5.5 V (both sides) | Matching supply ranges allow the same power rail design to be reused across either part. |
| Package | 8-pin SOIC (DWV) | 8-pin SOIC (DWV) | Identical package and pinout enable drop-in PCB compatibility between the two devices. |
| Typical Application | Isolated voltage sensing (e.g., DC-link, battery voltage) | Isolated current sensing via shunt resistor (e.g., motor drive, inverter) | The intended measurement function differs, so substitution requires changing the sensing element and signal chain design. |
| Input Bias Current | Very low (pA-range, high-impedance input) | Higher (µA-range, low-impedance input) | Bias current affects measurement error and loading; the high-impedance voltage input of one part is unsuitable for direct shunt sensing. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | AMC1311DWV | AMC1300DWV |
|---|---|---|
| Supplier | - | Texas Instruments |
| Part Status | Active | Active |
| Type | Isolation | Isolation |
| Applications | - | Current Sensing, Power Management |
| Mounting Type | Surface Mount | Surface Mount |
The AMC1311DWV is a precision isolated voltage amplifier designed for voltage sensing, featuring a high input impedance of 1 GΩ and a fixed gain of 1 V/V, with an input voltage range of ±1 V. The AMC1300DWV is an isolated amplifier optimized for current sensing via shunt resistors, featuring a low input impedance and a fixed gain of 8.2 V/V, with a linear input range of ±250 mV. The AMC1311 is intended for high-impedance voltage measurements, while the AMC1300 is intended for low-impedance shunt-based current measurements.
Yes. Both devices are offered in the same 8-pin SOIC (DWV) package with identical pin functions: VDD1, INP, INN, GND1 on the primary side and VDD2, OUTP, OUTN, GND2 on the secondary side. This allows a common PCB footprint, but the differing input structures and gains mean the surrounding circuitry must be redesigned for the intended signal type.
No, not directly. The AMC1311DWV has a ±1 V input range and a gain of 1 V/V, whereas the AMC1300DWV has a ±250 mV input range and a gain of 8.2 V/V optimized for shunt sensing. Using the AMC1311 for shunt current sensing would require a much larger shunt voltage drop and would not provide the same sensitivity or accuracy as the AMC1300 in that application.
The AMC1311DWV has a specified input voltage range of ±1 V with a gain of 1 V/V. The AMC1300DWV has a linear input voltage range of ±250 mV with a gain of 8.2 V/V. These ranges determine the appropriate sensing topology: high-impedance voltage division for the AMC1311 and low-value shunt resistance for the AMC1300.
Yes. Both the AMC1311DWV and AMC1300DWV are reinforced isolated amplifiers rated for 5 kV RMS isolation (per UL 1577) and are designed to meet reinforced isolation requirements in industrial and automotive applications. Designers should confirm the specific isolation ratings and certifications in the respective manufacturer datasheets for the target end equipment.
The AMC1311DWV is typically used for isolated voltage sensing in motor drives, inverters, and battery management systems where high input impedance is required. The AMC1300DWV is typically used for isolated current sensing with shunt resistors in motor control, power inverters, and industrial measurement systems. The choice depends on whether the measured quantity is a high-impedance voltage or a low-level shunt voltage.
No, they are not functionally interchangeable without redesign. Although they share the same package and pinout, their input ranges, input impedances, and gains differ significantly. Replacing one with the other requires recalculating the sensing network, verifying the signal chain gain, and validating accuracy and isolation performance against the manufacturer datasheets.