ADS1282HIPWR vs ADS1246IPW

Dieser detaillierte Vergleich von ADS1282HIPWR und ADS1246IPW bietet wertvolle Einblicke in deren Spezifikationen und Hauptmerkmale. Wir gehen ausführlich auf wichtige Faktoren ein, darunter RoHS-Konformität, REACH-Status, Serie, Montageart, Gehäusetyp und weitere relevante Eigenschaften. Die übersichtliche Darstellung der Unterschiede vereinfacht die Komponentenauswahl und erleichtert Ihnen die Wahl der optimalen Lösung für Ihre Anwendung.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1246IPW and ADS1282HIPWR are not functionally interchangeable. Although both are single-channel delta-sigma ADCs in TSSOP packages, they differ fundamentally in resolution, interface protocol, supply architecture, and target application class, so the ADS1282HIPWR cannot serve as a direct substitute for the ADS1246IPW without a full system redesign.

Different resolution class Different digital interface Different supply architecture Different application segment

Parts at a glance

Part A

ADS1282HIPWR

Texas Instruments

Lifecycle
Active
Stock
5203 Stückzahl
Series
Datenerfassung mit Analog to Digital Converters (ADC)
Part B

ADS1246IPW

Texas Instruments

Lifecycle
Active
Stock
6549 Stückzahl
Package
TSSOP-16
Series
Datenerfassung mit Analog to Digital Converters (ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1246IPW ADS1282HIPWR Why it matters
Resolution (bits) 24 31 Higher resolution enables finer measurement of small signal changes, which is critical for precision sensing applications.
Number of Input Channels 1 (single-ended/differential) 2 (differential) Channel count determines how many signal sources can be measured without external multiplexing.
Maximum Sample Rate 2 kSPS 4 kSPS Sample rate limits the bandwidth of signals that can be accurately digitized.
Interface Type SPI SPI A compatible serial interface simplifies drop-in replacement and firmware reuse.
Supply Voltage (Analog) 2.7 V to 5.25 V 4.75 V to 5.25 V (analog), 2.7 V to 3.6 V (digital) Supply range affects compatibility with the system power rail and low-voltage operation.
PGA / Gain Stage Yes (PGA, gains 1 to 128) Yes (PGA, gains 1 to 64) An integrated PGA allows direct connection of low-level sensors without external amplification.
Package TSSOP-16 TSSOP-28 Package footprint and pin count must match the PCB layout for physical substitutability.
Operating Temperature Range -40 °C to +105 °C -40 °C to +85 °C Temperature range determines suitability for harsh or industrial environments.
Input Type Single-ended or differential Differential Input configuration affects sensor wiring flexibility and noise immunity.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1282HIPWR ADS1246IPW
Part Status Active Active
Number of Bits 31 24
Sampling Rate (Per Second) 4k -
Number of Inputs 2 1
Input Type Differential Differential, Single Ended
Data Interface SPI SPI
Configuration ADC MUX-PGA-ADC
Number of A / D Converters 1 -
Architecture Sigma-Delta Sigma-Delta
Reference Type External External, Internal
Voltage - Supply, Analog 5V 2.7V ~ 5.25V
Voltage - Supply, Digital 1.65V ~ 3.6V 2.7V ~ 5.25V
Features PGA PGA, Temperature Sensor
Operating Temperature -40°C ~ 85°C -40°C ~ 105°C
Mounting Type Surface Mount -
Base Product Number ADS1282 -
Sampling Rate(Per Second) - 2k
Number of A/D Converters - 1

Frequently asked questions

What are the primary differences between the ADS1246IPW and ADS1282HIPWR?

The ADS1246IPW is a 24-bit, single-channel delta-sigma ADC in a 16-pin TSSOP package, while the ADS1282HIPWR is a 31-bit, dual-channel delta-sigma ADC in a 28-pin TSSOP package. The ADS1282H is designed for high-resolution seismic and energy exploration applications with a programmable gain amplifier and dual-channel simultaneous sampling, whereas the ADS1246 is a general-purpose low-noise ADC for sensor measurement.

Do the ADS1246IPW and ADS1282HIPWR have the same package and pinout?

No. The ADS1246IPW uses a 16-pin TSSOP (PW) package, and the ADS1282HIPWR uses a 28-pin TSSOP (PW) package. They are not pin-compatible and cannot be interchanged on the same PCB land pattern.

What are the resolution and data rate specifications of each device?

The ADS1246IPW provides 24-bit resolution with programmable data rates from 5 SPS to 2 kSPS. The ADS1282HIPWR provides 31-bit resolution with data rates from 250 SPS to 4 kSPS. These specifications are documented in the respective Texas Instruments datasheets.

How do the input channel configurations differ between the two ADCs?

The ADS1246IPW is a single-channel ADC with a flexible input multiplexer supporting differential and single-ended inputs. The ADS1282HIPWR is a dual-channel ADC with two simultaneous-sampling differential input channels, each with its own programmable gain amplifier.

Are the supply voltage requirements the same for the ADS1246IPW and ADS1282HIPWR?

No. The ADS1246IPW operates from an analog supply of 2.7 V to 5.25 V and a digital supply of 2.7 V to 5.25 V. The ADS1282HIPWR operates from an analog supply of 4.75 V to 5.25 V and a digital supply of 1.8 V to 3.6 V. Designers must verify supply rails against the respective datasheets.

Can the ADS1246IPW be used as a drop-in replacement for the ADS1282HIPWR?

No. The two devices differ in package pin count, resolution, channel count, supply requirements, and data rate ranges. A direct drop-in replacement is not possible; any substitution requires a full redesign and validation against the target application requirements.

What are the typical target applications for each device?

The ADS1246IPW is typically used in precision sensor measurement, temperature and pressure sensing, and industrial process control. The ADS1282HIPWR is targeted at high-resolution seismic data acquisition, energy exploration, and geophysical instrumentation requiring dual-channel simultaneous sampling.