ADS1282HIPWR
Texas Instruments
- Lifecycle
- Active
- Stock
- 5203 Stückzahl
- Series
- Datenerfassung mit Analog to Digital Converters (ADC)
Dieser detaillierte Vergleich von ADS1282HIPWR und ADS1248IPW bietet wertvolle Einblicke in deren Spezifikationen und Hauptmerkmale. Wir gehen ausführlich auf wichtige Faktoren ein, darunter RoHS-Konformität, REACH-Status, Serie, Montageart, Gehäusetyp und weitere relevante Eigenschaften. Die übersichtliche Darstellung der Unterschiede vereinfacht die Komponentenauswahl und erleichtert Ihnen die Wahl der optimalen Lösung für Ihre Anwendung.
Replacement verdict
The ADS1248IPW and ADS1282HIPWR are not drop-in replacements for one another. They differ in resolution and architecture, package and pinout, supply and reference requirements, and target application class, so a direct board-level substitution is not feasible without redesign and revalidation.
Texas Instruments
Texas Instruments
Rows are prioritized by design impact. Highlighted values require attention during substitution.
Key electrical and mechanical differences between the two devices
| Parameter | ADS1248IPW | ADS1282HIPWR | Why it matters |
|---|---|---|---|
| Resolution (bits) | 24 | 31 | Higher resolution enables finer measurement of small signal changes, which is critical for precision seismic and high-dynamic-range applications. |
| Number of input channels | 8 (single-ended) / 4 (differential) | 2 (differential) | Channel count determines how many sensors can be connected to a single ADC, affecting system architecture and multiplexing needs. |
| Maximum sample rate | 2 kSPS | 4 kSPS | Sample rate limits the bandwidth of signals that can be captured, which is essential for applications requiring higher-frequency data acquisition. |
| Interface type | SPI | SPI | Both use SPI, so the digital host interface is compatible, but the ADS1282 supports higher-speed SPI clocking for its faster output rates. |
| Supply voltage (analog) | 2.7 V to 5.25 V | 4.75 V to 5.25 V (analog) / 2.7 V to 3.6 V (digital) | Supply requirements affect power supply design and compatibility with low-voltage or single-supply systems. |
| PGA / gain stage | Integrated PGA (gain 1 to 128) | Integrated PGA (gain 1 to 64) | An integrated PGA allows direct connection of low-level sensors without external amplification, and the gain range affects the smallest resolvable input signal. |
| Package | TSSOP-28 | TSSOP-28 | Package compatibility affects PCB footprint and whether a drop-in replacement is physically possible. |
| Operating temperature range | -40 °C to +105 °C | -40 °C to +85 °C | The temperature range determines suitability for harsh or industrial environments and derating requirements. |
| Typical application focus | Sensor measurement, industrial process control, temperature/RTD sensing | Seismic and energy exploration, high-resolution instrumentation | Application focus indicates the intended signal chain and whether the part meets the noise, bandwidth, and dynamic range needs of a given design. |
Send your BOM and application constraints for technical and sourcing review.
Use manufacturer datasheets as the final authority.
| Specification | ADS1282HIPWR | ADS1248IPW |
|---|---|---|
| Part Status | Active | Active |
| Number of Bits | 31 | 24 |
| Sampling Rate (Per Second) | 4k | - |
| Number of Inputs | 2 | 4, 7 |
| Input Type | Differential | Differential, Single Ended |
| Data Interface | SPI | SPI |
| Configuration | ADC | MUX-PGA-ADC |
| Number of A / D Converters | 1 | - |
| Architecture | Sigma-Delta | Sigma-Delta |
| Reference Type | External | External, Internal |
| Voltage - Supply, Analog | 5V | 2.7V ~ 5.25V |
| Voltage - Supply, Digital | 1.65V ~ 3.6V | 2.7V ~ 5.25V |
| Features | PGA | PGA, Temperature Sensor |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 105°C |
| Mounting Type | Surface Mount | - |
| Base Product Number | ADS1282 | - |
| Sampling Rate(Per Second) | - | 2k |
| Number of A/D Converters | - | 1 |
The ADS1248IPW is a 24-bit, 8-channel (4 differential) delta-sigma ADC optimized for general-purpose sensor measurement with a programmable gain amplifier and integrated excitation current sources. The ADS1282HIPWR is a 31-bit, 2-channel (1 differential) delta-sigma ADC designed specifically for high-resolution seismic and energy exploration applications, featuring a low-noise programmable gain amplifier and selectable digital filters. The ADS1248 supports more input channels, while the ADS1282 offers higher resolution and a wider dynamic range.
No. The ADS1248IPW is supplied in a 28-pin TSSOP (PW) package, while the ADS1282HIPWR is supplied in a 28-pin TSSOP (PW) package as well, but the pin functions and internal architecture differ between the two devices. They are not pin-to-pin compatible, and the PCB layout and external component connections must be redesigned when substituting one for the other.
The ADS1248IPW provides 24-bit resolution with programmable data rates from 5 SPS to 2 kSPS. The ADS1282HIPWR provides 31-bit resolution with programmable data rates from 250 SPS to 4 kSPS. The ADS1282 achieves higher resolution and higher maximum output data rate, while the ADS1248 offers lower minimum data rates suitable for slow sensor measurements.
The ADS1248IPW offers 8 single-ended or 4 differential input channels, configurable through an input multiplexer. The ADS1282HIPWR offers 2 single-ended or 1 differential input channel. The ADS1248 is therefore better suited for multi-sensor systems, while the ADS1282 is intended for single-channel high-resolution measurements.
Yes. The ADS1248IPW includes a PGA with selectable gains of 1, 2, 4, 8, 16, 32, 64, and 128. The ADS1282HIPWR includes a low-noise PGA with selectable gains of 1, 2, 4, 8, 16, 32, and 64. Both PGAs allow direct connection of low-level sensor signals, but the gain ranges and noise performance differ.
The ADS1248IPW operates from an analog supply (AVDD) of 2.7 V to 5.25 V and a digital supply (DVDD) of 2.7 V to 5.25 V. The ADS1282HIPWR operates from an analog supply (AVDD) of 4.75 V to 5.25 V and a digital supply (DVDD) of 1.8 V to 3.6 V. The supply requirements are not interchangeable, and the power architecture must be verified for each device.
The ADS1282HIPWR is specifically designed for seismic and energy exploration applications, offering 31-bit resolution, low noise, and selectable digital filters tailored to geophysical signal processing. The ADS1248IPW is a general-purpose 24-bit ADC intended for industrial sensor and process control measurements, and it is not specified by the manufacturer for seismic-grade performance.
No. Although both devices use an SPI-compatible serial interface, their register maps, command sets, and configuration sequences differ. Firmware written for the ADS1248IPW cannot be used directly with the ADS1282HIPWR without modification to match the respective datasheet register definitions and timing requirements.