ADS1282HIPWR vs ADS1248IPW

Dieser detaillierte Vergleich von ADS1282HIPWR und ADS1248IPW bietet wertvolle Einblicke in deren Spezifikationen und Hauptmerkmale. Wir gehen ausführlich auf wichtige Faktoren ein, darunter RoHS-Konformität, REACH-Status, Serie, Montageart, Gehäusetyp und weitere relevante Eigenschaften. Die übersichtliche Darstellung der Unterschiede vereinfacht die Komponentenauswahl und erleichtert Ihnen die Wahl der optimalen Lösung für Ihre Anwendung.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1248IPW and ADS1282HIPWR are not drop-in replacements for one another. They differ in resolution and architecture, package and pinout, supply and reference requirements, and target application class, so a direct board-level substitution is not feasible without redesign and revalidation.

Different resolution and architecture Different package and pinout Different supply and reference requirements Different application class

Parts at a glance

Part A

ADS1282HIPWR

Texas Instruments

Lifecycle
Active
Stock
5203 Stückzahl
Series
Datenerfassung mit Analog to Digital Converters (ADC)
Part B

ADS1248IPW

Texas Instruments

Lifecycle
Active
Stock
2446 Stückzahl
Package
TSSOP-28
Series
Datenerfassung mit Analog to Digital Converters (ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1248IPW ADS1282HIPWR Why it matters
Resolution (bits) 24 31 Higher resolution enables finer measurement of small signal changes, which is critical for precision seismic and high-dynamic-range applications.
Number of input channels 8 (single-ended) / 4 (differential) 2 (differential) Channel count determines how many sensors can be connected to a single ADC, affecting system architecture and multiplexing needs.
Maximum sample rate 2 kSPS 4 kSPS Sample rate limits the bandwidth of signals that can be captured, which is essential for applications requiring higher-frequency data acquisition.
Interface type SPI SPI Both use SPI, so the digital host interface is compatible, but the ADS1282 supports higher-speed SPI clocking for its faster output rates.
Supply voltage (analog) 2.7 V to 5.25 V 4.75 V to 5.25 V (analog) / 2.7 V to 3.6 V (digital) Supply requirements affect power supply design and compatibility with low-voltage or single-supply systems.
PGA / gain stage Integrated PGA (gain 1 to 128) Integrated PGA (gain 1 to 64) An integrated PGA allows direct connection of low-level sensors without external amplification, and the gain range affects the smallest resolvable input signal.
Package TSSOP-28 TSSOP-28 Package compatibility affects PCB footprint and whether a drop-in replacement is physically possible.
Operating temperature range -40 °C to +105 °C -40 °C to +85 °C The temperature range determines suitability for harsh or industrial environments and derating requirements.
Typical application focus Sensor measurement, industrial process control, temperature/RTD sensing Seismic and energy exploration, high-resolution instrumentation Application focus indicates the intended signal chain and whether the part meets the noise, bandwidth, and dynamic range needs of a given design.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1282HIPWR ADS1248IPW
Part Status Active Active
Number of Bits 31 24
Sampling Rate (Per Second) 4k -
Number of Inputs 2 4, 7
Input Type Differential Differential, Single Ended
Data Interface SPI SPI
Configuration ADC MUX-PGA-ADC
Number of A / D Converters 1 -
Architecture Sigma-Delta Sigma-Delta
Reference Type External External, Internal
Voltage - Supply, Analog 5V 2.7V ~ 5.25V
Voltage - Supply, Digital 1.65V ~ 3.6V 2.7V ~ 5.25V
Features PGA PGA, Temperature Sensor
Operating Temperature -40°C ~ 85°C -40°C ~ 105°C
Mounting Type Surface Mount -
Base Product Number ADS1282 -
Sampling Rate(Per Second) - 2k
Number of A/D Converters - 1

Frequently asked questions

What are the primary functional differences between the ADS1248IPW and ADS1282HIPWR?

The ADS1248IPW is a 24-bit, 8-channel (4 differential) delta-sigma ADC optimized for general-purpose sensor measurement with a programmable gain amplifier and integrated excitation current sources. The ADS1282HIPWR is a 31-bit, 2-channel (1 differential) delta-sigma ADC designed specifically for high-resolution seismic and energy exploration applications, featuring a low-noise programmable gain amplifier and selectable digital filters. The ADS1248 supports more input channels, while the ADS1282 offers higher resolution and a wider dynamic range.

Are the ADS1248IPW and ADS1282HIPWR pin-to-pin or package compatible?

No. The ADS1248IPW is supplied in a 28-pin TSSOP (PW) package, while the ADS1282HIPWR is supplied in a 28-pin TSSOP (PW) package as well, but the pin functions and internal architecture differ between the two devices. They are not pin-to-pin compatible, and the PCB layout and external component connections must be redesigned when substituting one for the other.

What are the resolution and data rate specifications for each device?

The ADS1248IPW provides 24-bit resolution with programmable data rates from 5 SPS to 2 kSPS. The ADS1282HIPWR provides 31-bit resolution with programmable data rates from 250 SPS to 4 kSPS. The ADS1282 achieves higher resolution and higher maximum output data rate, while the ADS1248 offers lower minimum data rates suitable for slow sensor measurements.

How do the input channel configurations compare between the ADS1248IPW and ADS1282HIPWR?

The ADS1248IPW offers 8 single-ended or 4 differential input channels, configurable through an input multiplexer. The ADS1282HIPWR offers 2 single-ended or 1 differential input channel. The ADS1248 is therefore better suited for multi-sensor systems, while the ADS1282 is intended for single-channel high-resolution measurements.

Do both devices include a programmable gain amplifier (PGA)?

Yes. The ADS1248IPW includes a PGA with selectable gains of 1, 2, 4, 8, 16, 32, 64, and 128. The ADS1282HIPWR includes a low-noise PGA with selectable gains of 1, 2, 4, 8, 16, 32, and 64. Both PGAs allow direct connection of low-level sensor signals, but the gain ranges and noise performance differ.

What are the supply voltage requirements for the ADS1248IPW and ADS1282HIPWR?

The ADS1248IPW operates from an analog supply (AVDD) of 2.7 V to 5.25 V and a digital supply (DVDD) of 2.7 V to 5.25 V. The ADS1282HIPWR operates from an analog supply (AVDD) of 4.75 V to 5.25 V and a digital supply (DVDD) of 1.8 V to 3.6 V. The supply requirements are not interchangeable, and the power architecture must be verified for each device.

Which device is more suitable for seismic or energy exploration applications?

The ADS1282HIPWR is specifically designed for seismic and energy exploration applications, offering 31-bit resolution, low noise, and selectable digital filters tailored to geophysical signal processing. The ADS1248IPW is a general-purpose 24-bit ADC intended for industrial sensor and process control measurements, and it is not specified by the manufacturer for seismic-grade performance.

Can the ADS1248IPW and ADS1282HIPWR share the same SPI interface and microcontroller firmware?

No. Although both devices use an SPI-compatible serial interface, their register maps, command sets, and configuration sequences differ. Firmware written for the ADS1248IPW cannot be used directly with the ADS1282HIPWR without modification to match the respective datasheet register definitions and timing requirements.