ADS1210U vs ADS1251UG4

Dieser detaillierte Vergleich von ADS1210U und ADS1251UG4 bietet wertvolle Einblicke in deren Spezifikationen und Hauptmerkmale. Wir gehen ausführlich auf wichtige Faktoren ein, darunter RoHS-Konformität, REACH-Status, Serie, Montageart, Gehäusetyp und weitere relevante Eigenschaften. Die übersichtliche Darstellung der Unterschiede vereinfacht die Komponentenauswahl und erleichtert Ihnen die Wahl der optimalen Lösung für Ihre Anwendung.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1210U and ADS1251UG4 are both 24-bit delta-sigma analog-to-digital converters, but they differ fundamentally in resolution architecture, interface protocol, package footprint, and reference configuration, so the ADS1251UG4 cannot be treated as a drop-in substitute for the ADS1210U without a full board and firmware redesign.

Different interface protocol Different package footprint Different reference configuration Different data rate capability

Parts at a glance

Part A

ADS1210U

Texas Instruments

Lifecycle
Active
Stock
5384 Stückzahl
Package
SOIC-8
Series
Datenerfassung mit Analog to Digital Converters (ADC)
Part B

ADS1251UG4

Texas Instruments

Lifecycle
Active
Stock
2511 Stückzahl
Package
SOIC-8
Series
Datenerfassung mit Analog to Digital Converters (ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1210U ADS1251UG4 Why it matters
Resolution (bits) 24 24 Both are 24-bit delta-sigma ADCs, so nominal resolution is equivalent for high-precision measurement applications.
Number of input channels 1 (differential) 1 (differential) Both provide a single differential input, so channel count is not a differentiator for substitutability.
Maximum data rate (SPS) 16k 20k The ADS1251UG4 supports a higher maximum output rate, which affects achievable sampling speed in the application.
Interface type SPI-compatible serial SPI-compatible serial Both use a serial interface, so the host microcontroller connection scheme is broadly compatible.
Supply voltage (analog) 5 V 5 V Matching analog supply requirements simplifies power-rail design when substituting one part for the other.
Package type SOIC-18 SOIC-8 Different package footprints and pin counts mean the PCB layout must be redesigned; the parts are not drop-in replacements.
Operating temperature range -40 to +85 °C -40 to +85 °C Identical industrial temperature ranges mean both suit the same environmental conditions.
Internal PGA Yes (gain 1 to 16) No The ADS1210U includes a programmable gain amplifier for small-signal inputs, while the ADS1251UG4 lacks one, requiring external gain stages.
Reference input External differential reference External differential reference Both require an external reference, so reference design considerations are similar for either part.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1210U ADS1251UG4
Supplier - Texas Instruments
Part Status Last Time Buy Discontinued at Digi-Key
Number of Bits 24 24
Sampling Rate(Per Second) 16k 20k
Number of Inputs 1 1
Input Type Differential Differential
Data Interface SPI SPI
Configuration PGA-ADC ADC
Number of A/D Converters 1 1
Architecture Sigma-Delta Sigma-Delta
Reference Type External, Internal External
Voltage - Supply, Analog 5V 5V
Voltage - Supply, Digital 5V 5V
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C
Features PGA -

Frequently asked questions

What are the key architectural differences between the ADS1210U and ADS1251UG4?

The ADS1210U is a 24-bit delta-sigma ADC with a programmable gain amplifier (PGA) offering gains from 1 to 16, a flexible input range, and a maximum data rate of 15.6 kSPS. The ADS1251UG4 is a 24-bit delta-sigma ADC with a fixed gain of 1, no PGA, and a maximum data rate of 20 kSPS. The ADS1210U includes a serial interface with SPI compatibility and supports both differential and single-ended inputs, while the ADS1251UG4 provides a simpler, lower-power design with a fixed input range and a two-wire serial interface.

Are the ADS1210U and ADS1251UG4 pin-compatible?

No. The ADS1210U is offered in a 24-pin SOIC (DW) package, while the ADS1251UG4 is offered in an 8-pin SOIC (D) package. The pin counts, pin functions, and PCB land patterns differ, so they are not drop-in replacements for each other.

Which device offers a higher maximum data rate?

The ADS1251UG4 supports a maximum data rate of 20 kSPS, while the ADS1210U supports a maximum data rate of 15.6 kSPS. The ADS1251UG4 therefore provides a higher maximum output rate, but the ADS1210U offers programmable gain and more flexible input configuration.

Do both devices include a programmable gain amplifier (PGA)?

No. The ADS1210U includes a PGA with selectable gains of 1, 2, 4, 8, and 16, allowing direct connection of low-level sensors. The ADS1251UG4 does not include a PGA; it has a fixed gain of 1, so external signal conditioning may be required for low-level inputs.

How do the power consumption specifications compare?

The ADS1210U typically consumes about 10 mW at a 5 V supply in normal operation. The ADS1251UG4 is specified for low-power operation, typically consuming about 5 mW at a 5 V supply. Exact consumption depends on supply voltage, data rate, and operating mode, so the datasheet should be consulted for the target conditions.

What serial interface does each device provide?

The ADS1210U provides a serial interface that is SPI-compatible, with separate data input and output lines and a serial clock, supporting full-duplex communication. The ADS1251UG4 provides a simpler two-wire serial interface consisting of a serial clock and a data output line, with no data input line for register configuration.

Can the ADS1251UG4 be used as a direct replacement for the ADS1210U in an existing design?

No. The devices differ in package size and pinout, gain architecture, maximum data rate, and serial interface. A direct replacement would require PCB redesign, firmware changes for the different interface and configuration model, and revalidation of the analog input range and gain requirements against the system specifications.