ADS1259IPWR vs ADS1222IPWRG4

Dieser detaillierte Vergleich von ADS1259IPWR und ADS1222IPWRG4 bietet wertvolle Einblicke in deren Spezifikationen und Hauptmerkmale. Wir gehen ausführlich auf wichtige Faktoren ein, darunter RoHS-Konformität, REACH-Status, Serie, Montageart, Gehäusetyp und weitere relevante Eigenschaften. Die übersichtliche Darstellung der Unterschiede vereinfacht die Komponentenauswahl und erleichtert Ihnen die Wahl der optimalen Lösung für Ihre Anwendung.

Technical review by ETEI Component Engineering Source: manufacturer documentation

Replacement verdict

Not a drop-in replacement

The ADS1259IPWR and ADS1222IPWRG4 are not drop-in replacements for one another. They differ in resolution, architecture, input channel configuration, and package footprint, so substituting one for the other requires full schematic and layout redesign as well as firmware revalidation.

Different resolution Different ADC architecture Different input channel count Different package footprint

Parts at a glance

Part A

ADS1259IPWR

Texas Instruments

Lifecycle
Active
Stock
6414 Stückzahl
Package
TSSOP-20
Series
Datenerfassung mit Analog to Digital Converters (ADC)
Part B

ADS1222IPWRG4

Texas Instruments

Lifecycle
Active
Stock
4722 Stückzahl
Package
TSSOP-14
Series
Datenerfassung mit Analog to Digital Converters (ADC)

Key differences

Rows are prioritized by design impact. Highlighted values require attention during substitution.

Key electrical and mechanical differences between the two devices

Parameter ADS1259IPWR ADS1222IPWRG4 Why it matters
Resolution (bits) 24 24 Both are 24-bit delta-sigma ADCs, so resolution alone does not differentiate them for substitutability.
Number of input channels 1 (single-ended) 2 (differential) Channel count and input configuration determine how many signals can be measured and whether differential measurement is supported.
Maximum sample rate 14 kSPS 2 kSPS Sample rate limits the bandwidth of signals that can be accurately digitized; the ADS1259 supports significantly faster conversion.
Interface type SPI SPI Both use SPI, so the host microcontroller interface is compatible, easing drop-in replacement at the digital level.
Supply voltage (analog) 5 V (4.75 V to 5.25 V) 2.7 V to 5.5 V The wider analog supply range of the ADS1222 allows operation at lower voltages, affecting system power design and compatibility.
Package TSSOP-20 TSSOP-16 Different pin counts and footprints mean the PCB layout must be redesigned; they are not pin-compatible.
Operating temperature range -40°C to +105°C -40°C to +85°C The wider temperature range of the ADS1259 suits harsher environments, while the ADS1222 is limited to standard industrial conditions.
Internal PGA / gain No (external gain) Yes (PGA, gain 1 to 128) An integrated PGA allows direct amplification of small sensor signals, simplifying the analog front end for low-level inputs.
Input voltage range 0 V to VREF (unipolar) Differential, ±VREF/gain Input range and polarity determine whether the ADC can directly digitize bipolar or only unipolar signals without external conditioning.

Need help validating a replacement?

Send your BOM and application constraints for technical and sourcing review.

Full specification comparison

Use manufacturer datasheets as the final authority.

Specification ADS1259IPWR ADS1222IPWRG4
Supplier - Texas Instruments
Part Status Active Discontinued at Digi-Key
Number of Bits 24 24
Sampling Rate(Per Second) 14k 240
Number of Inputs 1 2
Input Type Differential, Single Ended Differential, Single Ended
Data Interface SPI SPI
Configuration ADC MUX-ADC
Number of A/D Converters 1 1
Architecture Sigma-Delta Sigma-Delta
Reference Type External External
Voltage - Supply, Analog 5V 2.7V ~ 5.5V
Voltage - Supply, Digital 2.7V ~ 5.25V 2.7V ~ 5.5V
Features PGA Temperature Sensor
Operating Temperature -40°C ~ 105°C -40°C ~ 85°C

Frequently asked questions

What are the primary functional differences between the ADS1259IPWR and ADS1222IPWRG4?

The ADS1259IPWR is a 24-bit, 14.4-kSPS delta-sigma ADC with an integrated low-noise PGA and a precision voltage reference, designed for high-resolution industrial measurement. The ADS1222IPWRG4 is a 24-bit, 2-kSPS delta-sigma ADC with a fixed-gain PGA and no integrated reference, intended for lower-speed, cost-sensitive sensor applications. The ADS1259 offers higher throughput and integrated reference, while the ADS1222 provides lower power and a smaller feature set.

Are the ADS1259IPWR and ADS1222IPWRG4 pin-compatible?

No. The ADS1259IPWR is supplied in a TSSOP-20 package, while the ADS1222IPWRG4 is supplied in a TSSOP-16 package. The pin counts and pin functions differ, so they are not drop-in replacements and require different PCB land patterns.

How do the maximum sample rates of the two ADCs compare?

The ADS1259IPWR supports data rates up to 14.4 kSPS in its high-speed mode. The ADS1222IPWRG4 supports data rates up to 2 kSPS. The ADS1259 is therefore better suited for applications requiring faster signal acquisition, while the ADS1222 targets low-speed precision sensing.

Do both devices include an integrated voltage reference?

No. The ADS1259IPWR integrates a precision voltage reference, which reduces external component count. The ADS1222IPWRG4 does not include an integrated reference and requires an external reference voltage for ratiometric or absolute measurements.

How do the PGA specifications differ between the ADS1259IPWR and ADS1222IPWRG4?

The ADS1259IPWR includes a low-noise PGA with selectable gains of 1 to 128, supporting direct connection of low-level sensors. The ADS1222IPWRG4 includes a fixed-gain PGA of 1 to 128 as well, but its noise and throughput performance are optimized for lower-speed operation. Designers should compare noise density and effective resolution at the target gain and data rate.

What are the typical supply voltage and power consumption differences?

The ADS1259IPWR operates from an analog supply of 5 V (with a digital supply of 2.7 V to 5.25 V) and typically consumes about 13 mW at 14.4 kSPS. The ADS1222IPWRG4 operates from a single 2.7 V to 5.5 V supply and typically consumes about 1.2 mW at 2 kSPS. The ADS1222 is significantly lower power, consistent with its lower throughput.

Which device is more suitable for high-resolution industrial measurement systems?

The ADS1259IPWR is generally more suitable for high-resolution industrial measurement because it combines 24-bit resolution, up to 14.4 kSPS throughput, a low-noise PGA, and an integrated precision reference. The ADS1222IPWRG4 is better suited to lower-speed, lower-power sensor interfaces where an external reference is acceptable.

Can the ADS1222IPWRG4 directly replace the ADS1259IPWR in an existing design?

No. Direct replacement is not possible without redesign because the two devices differ in package (TSSOP-16 vs TSSOP-20), pinout, maximum sample rate, reference architecture, and supply/power characteristics. Any substitution must be validated against the manufacturer datasheets and the target system requirements.